CDPVH - FRESH KOTE EXTERIOR PRIMER, 056196

  • MSDS: CDPVH
  • Manufacturer: M A BRUDER AND SONS INC
  • Product Name: FRESH KOTE EXTERIOR PRIMER, 056196
  • National Stock Number: 8010-00N077545
Product Identification

Product ID:FRESH KOTE EXTERIOR PRIMER, 056196
MSDS Date:02/15/1993
FSC:8010
NIIN:00N077545
MSDS Number: CDPVH

Responsible Party
M A BRUDER & SONS INC
600 REED ROAD
BROOMALL, PA 19008
US

Emergency Phone: 215-353-5100

Info Phone: 215-359-3635

Cage: 85519

Contractor
M A BRUDER & SONS INC
600 BROOMALL, PA 19008 US

Telephone: 610-353-5100;610-359-3635

Cage: 85519

Ingredients

TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 11-30%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9495


DIATOMACEOUS EARTH

CAS: 68855-54-9

Fraction By Weight: 1-10%

OSHA PEL 6 MG/M3 (MFR)

ACGIH TLV: 10 MG/M3 (MFR)


TALC (POWDER), CONTAINING NO ASBESTOS FIBEERS; (TALC)

CAS: 14807-96-6

RTECS: WW2710000

Fraction By Weight: 11-30%

OSHA PEL 20 MPPCF Z-3

ACGIH TLV: 2 MG/M3 RDUST; 9495


SILICATE, MICA; (MICA)

CAS: 12001-26-2

RTECS: VV8760000

Fraction By Weight: 1-10%

OSHA PEL 20 MPPCF; Z-3

ACGIH TLV: 3 MG/M3 RDUST; 9495


2.0

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 11-30%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM; 9495


1 @ 25C

CAS: 64475-85-0

RTECS: PY8240000

Fraction By Weight: 1-10%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


LINSEED OIL

CAS: 8001-26-1

RTECS: OI9690000

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K


ALKYD RESIN

CAS: 67762-15-6

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K


INTENTIONAL MISUSE BY DELIB CONCENTRATING

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: IRRIT OF RESP TRACT. PRLNG
INHAL MAY LEAD TO FATG. DROWS, DIZZ & LTHEAD, HDCH, LACK OF
COORDINATION, NAUS, VOMIT, CNS DEPRESS, ANESTH EFT/NARCOS. SKIN:
IRRIT OF SKIN. PRLNG/RPTD CNTCT CAN CAUSE DERM, DEFAT. EYE: IRRIT
OF EYES. PRLNG/RPTD CNTCT CAN CAUSE BLURRED VISION, REDNESS OF
EYES, TEARING (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:OF EYES, SEVERE EYE IRRIT. INGEST:AMTS
INGESTED INCIDENTAL TO CONSUMER & INDUS HNDLG ARE NOT LIKELY TO
CAUSE INJURY; HOWEVER, INGEST OF LARGER AMTS MAY CAUSE LUNG INFLAMM
& DMG DUE TO ASPIR O F MATL INTO LUNGS. RPTS HAVE ASSOCD RPT& PRLNG
OCCUP OVER-EXP TO SOLV W/PERM BRAIN & NERVOUS SYS DMG. (ING 9)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. RESTORE & SUPPORT CONTINUED
BRTHG. HAVE TRAINED PERSON GIVE OXYGEN IF NEC. GET EMER MED ATTN.
SKIN: WASH OFF QUICKLY W/PLENTY OF H*2O, THEN SOAP & H*2O; REMOVE
CONTAMD CLTH G. WASH CONTAMD CLTHG BEFORE REUSE. EYE: FLUSH IMMED
W/LRG AMTS OF H*2O, ESP UNDER LIDS, FOR AT LEAST 15 MIN. OBTAIN
EMER MED TREATMENT. INGESTION: IF SWALLOWED, OBTAIN MEDICAL
TREATMENT IMMEDIATELY.

Fire Fighting

Flash Point Method:TCC
Flash Point:>42F,>6C
Lower Limits:SEE INGRED
Extinguishing Media:DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER MAY BE USED TO COOL AND PROTECT EXPOSED
CONTAINERS.
Unusual Fire/Explosion Hazard:CLSD CNTNRS MAY EXPLODE WHEN EXPOSED TO
EXTREME HEAT/FIRE. VAPS CAN FOAM EXPLO MIX IN AIR AT ELEVATED TEMP.
MAY DECOMPOSE UNDER FIRE CNDTNS EMITTING (SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAME, HOT
SURFACES, AND ELECTRICAL, STATIC SPARKS). VENTILATE AREA AND AVOID
BREATHING VAPORS. CONTAIN AND REMOVE WITH INERT ABSORBENT MATERIAL
USING NON-SPARKING TOOL S.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE IN SUN OR ABOVE 100
DEGREE F. STORE LARGE QUANTITIES IN BUILDINGS DESIGNED FOR STORAGE
OF FLAMMABLE OR COMBUSTIBLE LIQUIDS.
Other Precautions:DO NOT TAKE INTERNALLY. DO NOT WELD/FLAME CUT W/OUT
PROPER VENT TO INSURE THE AREA IS FREE OF FLAMM VAPS. DO NOT CUT,
PUNCTURE/WELD ON/NEAR THE CNTNR. ENTRANCE INTO CLSD STOR TANKS-USE
APPROP NIOSH AP PROVED RESP/AIRLINE FOR POSS (SUPDAT)

Exposure Controls

Respiratory Protection:CONTROL ENVIRONMENTAL CONCENTRATIONS BELOW
APPLICABLE STANDARDS. APPROVED CHEMICAL MECHANICAL FILTER
RESPIRATOR DESIGNED TO REMOVE A COMBINATION OF PARTICULATE AND
VAPORS (NIOSH TC23C OR EQUIVALENT).
Ventilation:ALL APPLICATION AREAS SHOULD BE VENTILATED I/A/W OSHA
REGULATION 29 CFR 1910 DURING USE & UNTIL AREA IS FREE OF VAPORS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ: IRRITANT AND/OR TOXIC GASES. OTHER PREC: EXPOS TO SOLVENT OR
CHEMICAL FUMES. RAGS/WASTE CONTAINING OIL BASED PAINT/VARNISH THAT
PRESENT LARGE AIR-TO-OIL INTERFACE WILL OXIDIZE & MAY IGNITE
SPONTANEOUSLY & SHOULD BE PLACED IN METAL CONTAINER. KEEP OUT OF
THE REACH OF CHILDREN.

Chemical Properties

Boiling Pt:B.P. Text:>245F,>118C
Vapor Pres:SEE INGRED
Spec Gravity:1.19-1.67
Evaporation Rate & Reference:SLOWER THAN ETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:38-60

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS, ACIDS, BASES, AMINES.
Stability Condition to Avoid:ELEVATED TEMPERATURES. CONTACT WITH
OXIDIZING AGENTS.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. AVOID DISCHARGE TO NATURAL WATERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.